GSM900 Provider Switzerland

 

from (MHz)

to (MHz)

Abbreviation

Transmitting power

Range

Modulation

Pulsed

Provider

Comments

Description

 

880,1

883,3

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

ORANGE

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

883,5

889,9

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

890,1

902,3

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

Swisscom

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

902,5

907,3

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

907,5

908,9

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

Swisscom

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

909,1

914,9

GSM 900 (UL)

2W ERP (Peak)

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Power output between 20mW-2W (Peak)

Mobile communications (D-Netz)

 

925,1

928,3

GSM 900 (DL)

400W ERP

32km

GMSK

YES

ORANGE

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

928,5

934,9

GSM 900 (DL)

400W ERP

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

935,1

947,3

GSM 900 (DL)

400W ERP

32km

GMSK

YES

Swisscom

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

947,5

952,3

GSM 900 (DL)

400W ERP

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

952,5

953,9

GSM 900 (DL)

400W ERP

32km

GMSK

YES

Swisscom

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

954,1

959,9

GSM 900 (DL)

400W ERP

32km

GMSK

YES

TDC Sunrise

Pulsed at 217Hz. Control channel with 1.736Hz. Power output between 0,5-400W ERP

Mobile communications (D-Netz)

 

 

 

TDC Sunrise

 

Swisscom

 

ORANGE

 

FREQUENCY SPECIFICATIONS:

Partially rounded to 0,1MHz. Some frequency blocks have been combined into one bigger block.

 

ABBREVIATION:

Partially internationally accepted labels or specific abbreviations used by the "Autoident" feature of Aaronia SPECTRAN spectrum analysers /electrosmog detectors

 

TRANSMITTING POWER:

Maximum permitted or regular transmitting power

 

RANGE:

Always indicated the maximum or average USABLE distance, not the maximum MEASURABLE distance.

MODULATION:

Where "various" is indicated, use of modulation modes varies widely.

PULSING:

Where "YES" is indicated, pulsing might be used only intermittently, in specific modes, or by specific devices.

PROVIDER:

Typical provider. Either the name of the company, or "private" is indicated for mainly non-commercial use. "commercial" is indicated for mainly commercial use, "aerial" for mainly aerial radio, "military" = mainly military use

 

DESCRIPTION:

Detailed description, often with application examples

 

(UL):

"Uplink" mostly means "handheld device" (portable transmitter which transmits towards a tower, like mobile phones)

 

(DL):

"Downlink" mostly means "base station" (fixed transmitter which transmits towards portable devices, like cell towers)

 

MW=Megawatts

=1.000.000Watts

 

kW=Kilowatts

=1.000Watts

 

W=Watts

=1.000 MilliWatts

 

mW=Milliwatts

=0,001Watts

 

 

© Aaronia AG, DE-54597 Euscheid, www.Spectran.com, Phone ++49(0)6556-93033 / NO responsibility taken for completeness or correctness.

 

 

WARNING:
Full or partial reproduction or other publication of this material in homepages is PROHIBITED without written permission from Aaronia AG. As our tables have been popular for unauthorized third-party use in the past, you should be aware of the fact that we will instantly persue unauthorized use. However, PERMISSION to use and publish this material is mostly FREE and NOT A PROBLEM - just contact us BEFORE using our tables.